XBD-L Series Vertical Single-Stage Fire Pressure Stabilizing Pump
Vertical single-stage fire pressure stabilizing pump for fire hydrant, sprinkler and water spray systems. Compact vertical design with stable pressure regulation for reliable fire protection in residential, commercial and industrial buildings.
Key Specifications
| Flow Rate | 1-30 L/s |
| Pressure | 0.3-1.6 MPa |
| Power | 0.75-30 kW |
Product Overview
The XBD-L Series Vertical Single-Stage Fire Pressure Stabilizing Pump is a compact vertical single-stage centrifugal pump designed specifically for fire protection pressure stabilizing applications. This integrated electromechanical pump unit maintains system pressure within the fire water network during standby conditions, preventing unnecessary activation of the main fire pumps due to minor pressure fluctuations.
The vertical inline design offers a compact footprint with straightforward installation directly in the pipeline, making it ideal for installations with limited pump room space. Depending on regional terminology, it may also be referred to as a Fire Jockey Pump, Fire Pressure Maintenance Pump, Vertical Single-Stage Fire Pressure Stabilizing Pump or XBD-LFire Pump.
Key Features
- High operating efficiency with optimised single-stage impeller design for reduced energy consumption during standby operation
- Integrated electromechanical design minimises installation footprint and simplifies pipeline integration
- Compact vertical inline arrangement suitable for direct pipeline installation
- Stable operating performance with rational structural design for long-term reliability
- Extended service life with quality materials and robust construction
- Reliable pressure maintenance for fire protection systems during standby conditions
Applications
- Fire hydrant system pressure stabilisation in residential and commercial buildings
- Automatic sprinkler system pressure maintenance in office complexes and hotels
- Water mist fire suppression system pressure stabilisation
- Fire protection water network pressure maintenance for factories and industrial facilities
- Hospital fire protection system pressure stabilising
- Commercial building fire hydrant and sprinkler system pressure maintenance
Customer Benefits
Energy-Efficient Standby Operation
The hydraulically optimised single-stage impeller design and efficient motor selection reduce power consumption during continuous standby operation, lowering utility costs over the pump service life.
Space-Saving Integrated Design
The integrated electromechanical vertical inline design enables direct pipeline installation with minimal additional space requirements, making the XBD-L Series ideal for installations with confined pump rooms.
Stable Pressure Maintenance
The single-stage impeller configuration provides consistent pressure output to maintain the fire water network within the required pressure range during standby conditions, preventing unnecessary activation of the main fire pumps.
Extended Service Life
The rational structural design and quality materials reduce component wear and extend maintenance intervals, lowering total cost of ownership over the pump service life.
Reliable Fire System Readiness
With flow rates from 1 to 120 L/s and pressures up to 1.52 MPa, the XBD-L Series provides dependable pressure stabilisation to ensure fire protection systems remain ready for immediate activation.
Wide Operating Range
With pressures from 0.32 to 1.52 MPa and outlet diameters from DN32 to DN250, the XBD-L Series covers a broad range of fire protection pressure stabilizing requirements across diverse building types.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Series | XBD-L Series |
| Pump Type | Vertical single-stage fire pressure stabilizing pump |
| Flow Rate | 1-120 L/s |
| Pressure | 0.32-1.52 MPa |
| Motor Power | 0.75-200 kW |
| Rotational Speed | 2900 r/min |
| Outlet Diameter | DN32-DN250 |
| Installation Type | Vertical inline |
Selection Guidance
To select the appropriate XBD-L Series fire pressure stabilizing pump, please provide the following information:
- Required standby flow rate (L/s)
- Required system pressure (MPa or bar)
- Fire protection system type (hydrant, sprinkler, water mist)
- Building type and occupancy classification
- Available installation space and pipeline configuration
- Available voltage and frequency
- Applicable fire protection standards and codes
Final model selection should be confirmed according to the actual system pressure requirements and applicable fire protection standards.
Installation and Maintenance
Installation Guidance
The pump should be installed directly in the pipeline with adequate clearance for inspection and maintenance. The inlet and outlet pipelines must be properly supported so that no external load is transferred to the pump connections. The integrated electromechanical design enables straightforward inline installation.
Pre-Start Inspection
Before starting the pump, confirm the following:
- Pump is securely mounted and properly aligned in the pipeline
- Pipeline connections are complete and properly sealed
- Inlet and outlet passages are unobstructed
- Motor wiring is correct and terminals are secure
- Rotational direction matches the arrow indicated on the pump casing
- All fasteners are properly tightened
Routine Maintenance
Regular inspection should include:
- Checking mechanical seals for leakage
- Monitoring motor bearing temperature and vibration levels
- Verifying that the pump maintains the required system pressure
- Cleaning strainers and filters when necessary
- Inspecting all pipeline connections for signs of wear or leakage
Available Configurations
- Flow rates from 1 to 120 L/s
- Pressure range from 0.32 to 1.52 MPa
- Motor powers from 0.75 to 200 kW
- Rotational speed: 2900 r/min
- Outlet diameters from DN32 to DN250
- Integrated control panels with automatic pressure monitoring and pump cycling
FAQs
What is a fire pressure stabilizing pump?
A fire pressure stabilizing pump (also known as a fire jockey pump) maintains the required pressure in the fire water network during standby conditions, preventing unnecessary activation of the main fire pumps due to minor pressure fluctuations or small leaks.
What is the flow range of the XBD-L Series?
The XBD-L Series offers flow rates from 1 to 120 L/s, suitable for fire protection pressure stabilizing applications.
What is the pressure range?
Available pressures range from 0.32 to 1.52 MPa.
What fire protection systems can this pump serve?
It is suitable for fire hydrant systems, automatic sprinkler systems and water mist fire suppression systems in residential, commercial, industrial and institutional buildings.
Why use an integrated electromechanical design?
The integrated electromechanical vertical inline design enables direct pipeline installation with minimal additional space requirements, reducing installation complexity and pump room footprint.
What maintenance is required?
Regular maintenance includes checking mechanical seals for leakage, monitoring motor bearing temperature and vibration, verifying system pressure maintenance, and inspecting pipeline connections.
Contact Chaodun
For product selection, technical data, performance information or project quotations, please contact Shanghai Chaodun Machinery Manufacturing Group Co., Ltd.