XBD-D Series Horizontal Multistage Fire Pump

XBD-D Series Horizontal Multistage Fire Pump

Main
Angle

XBD-D Series Horizontal Multistage Fire Pump

Horizontal multistage fire pump for high-head fire protection water supply in high-rise buildings, industrial plants and large commercial facilities. Multistage impeller design delivers high pressure with stable performance.

Key Specifications

Flow Rate 10-100 L/s
Head 0.3-2.4 MPa
Power 30-450 kW

Inquiry Now →

Product Overview

The XBD-D Series Horizontal Multistage Fire Pump is a horizontal multistage centrifugal pump designed for fire protection applications requiring elevated head. The multistage impeller configuration delivers high pressure across multiple stages, making it suitable for high-rise building fire protection and long-distance fire water delivery applications.

This fire pump is designed to provide reliable fire protection water supply for fire hydrant systems, automatic sprinkler systems and water mist suppression systems. Depending on regional terminology, it may also be referred to as a Horizontal Multistage Fire Pump, Multistage Fire Pump, Horizontal Multistage Fire Pump or Multistage Fire Pump.

Key Features

  • Horizontal multistage impeller configuration delivers high head for elevated fire protection requirements
  • Suitable for high-rise building fire protection and long-distance fire water delivery
  • Reliable fire protection water supply for hydrant, sprinkler and water mist systems
  • Robust structural design for extended service life in demanding fire protection applications
  • Suitable for both fire protection and mine water supply/drainage applications
  • Efficient hydraulic design for reduced energy consumption during fire pump operation

Applications

  • Fire hydrant fire suppression systems in high-rise residential and commercial buildings
  • Automatic sprinkler fire protection systems requiring elevated supply pressure
  • Water mist fire suppression systems
  • Fire protection water supply for office complexes, hotels and commercial buildings
  • Industrial facility fire protection including factories
  • Hospital fire protection systems and mine water supply/drainage applications

Customer Benefits

High-Head Capability

The horizontal multistage impeller configuration delivers pressures up to 2.0 MPa, making the XBD-D Series suitable for high-rise building fire protection and applications requiring elevated supply pressure.

Wide Flow Range

With flow rates from 40 to 350 L/s, the XBD-D Series covers a broad spectrum of fire protection system requirements, from small commercial installations to large industrial facilities.

Reliable Fire System Readiness

The robust structural design and rational hydraulic configuration ensure dependable fire protection water supply during emergency events, maintaining system pressure and flow under demanding conditions.

Versatile Application Range

In addition to fire protection duties, the XBD-D Series can serve mine water supply and drainage applications, providing a versatile pumping solution for industrial installations.

Efficient Operation

The hydraulically optimised impeller design and efficient motor selection reduce power consumption during fire pump test runs and emergency operation, lowering operating costs.

Extended Service Life

The robust construction and quality materials reduce component wear and extend maintenance intervals, lowering total cost of ownership over the pump service life.

Technical Specifications

Parameter Specification
Product Series XBD-D Series
Pump Type Horizontal multistage fire pump
Flow Rate 40-350 L/s
Pressure 0.3-2.0 MPa
Motor Power 30-450 kW
Installation Type Horizontal

Selection Guidance

To select the appropriate XBD-D Series horizontal multistage fire pump, please provide the following information:

  • Required flow rate (L/s)
  • Required pressure (MPa or bar)
  • Fire protection system type (hydrant, sprinkler, water mist)
  • Building type and occupancy classification
  • Available installation space and pump room dimensions
  • Available voltage and frequency
  • Required duty point on the pump curve
  • Applicable fire protection standards and codes

Final model selection should be confirmed according to the actual duty point, system requirements and applicable fire protection standards.

Installation and Maintenance

Installation Guidance

The pump should be installed on a rigid, level foundation with adequate clearance for inspection and maintenance access. The suction and discharge piping must be independently supported to prevent load transfer to the pump flanges.

Pre-Start Inspection

Before starting the pump, confirm the following:

  • Pump is securely mounted and level
  • Suction and discharge piping connections are complete and leak-free
  • Pump casing is properly filled and primed
  • Motor wiring and connections are secure
  • Rotational direction matches the arrow indicated on the pump casing
  • All fasteners are properly tightened

Routine Maintenance

Regular inspection should include:

  • Checking mechanical seals for leakage
  • Monitoring motor bearing temperature and vibration levels
  • Verifying that the pump maintains the required flow and pressure during test runs
  • Inspecting all pipeline connections for signs of leakage
  • Cleaning strainers and filters when necessary

Available Configurations

  • Flow rates from 40 to 350 L/s
  • Pressure range from 0.3 to 2.0 MPa
  • Motor powers from 30 to 450 kW
  • Various stage configurations for different head requirements
  • Electric motor or diesel engine drive options
  • Integrated control panels with automatic start and monitoring

FAQs

What is a horizontal multistage fire pump?

It is a fire pump with a horizontal multistage impeller configuration that delivers high pressure across multiple stages, suitable for high-rise building fire protection and applications requiring elevated supply pressure.

What is the flow range of the XBD-D Series?

The XBD-D Series offers flow rates from 40 to 350 L/s, suitable for medium to large fire protection systems.

What is the pressure range?

Available pressures range from 0.3 to 2.0 MPa.

What fire protection systems can this pump serve?

It is suitable for fire hydrant systems, automatic sprinkler systems and water mist fire suppression systems in residential, commercial, industrial and institutional buildings.

Why use a multistage design for fire protection?

The multistage impeller configuration achieves the required high pressure for elevated fire protection applications, such as high-rise building fire protection and long-distance fire water delivery, from a single pump unit.

Can this pump be used for mine drainage?

Yes. The XBD-D Series is also suitable for mine water supply and drainage applications in addition to fire protection duties.

Contact Chaodun

For product selection, technical data, performance information or project quotations, please contact Shanghai Chaodun Machinery Manufacturing Group Co., Ltd.

Website: https://chaodunpump.com

Email: Suzion@chaodunpump.com

WhatsApp: +44 751 8050 473

Scroll to Top